Murata · Japan · SIP thick film

Résistance de remplacement haute tension série Murata MHR0312SA

MHR0312SA is the substrate series, not a complete part number: the 12.6 mm long, 5 mm high member of the Murata MHR SIP line, 0.6 W, 5 kV single use and 7.5 kV once molded. HVC builds the same outline as a thick film plate with a cut body, so the lead pitch and the seated height stay where the PCB expects them.

Résistance haute tension à couche épaisse SIP remplaçant la Murata MHR0312SA

Référence croisée MHR0312SA

ItemMurata MHR0312SAHVC alternative
Body (L × H)12.6 × 5 mm5.0 mm high, cut to 12.6 mm long, cut to 12.6 mm
Lead pitch10.16 mmSame, set on the drawing
Rated power0.6 W1 W
Rated voltage5 kV single / 7.5 kV molded5 kV air, continuous
Resistance1–1000 MΩ, nine stepsAny value in range
ModelMHR0312SAHVRGHP5.13

Same outline. Murata figures are the catalogue values for this body. HVC ratings are continuous values in air. Confirm the medium and the duty in the RFQ.

Pourquoi les acheteurs arrivent avec un numéro MHR0312SA

Il ne s'agit généralement pas d'un bon de commande. C'est une réparation, un plan provenant d'une machine plus ancienne ou une conception héritée d'un fournisseur qui ne la prend plus en charge. Le numéro est la seule information fiable, et la question est simplement de savoir si la pièce est encore disponible selon les spécifications du plan.

That is a different question from price. Murata builds MHR0312SA in nine resistance steps; anything between the steps, anything above 0.6 W, or anything above 5 kV in air has no catalogue answer at all, and that is where a cut-to-outline plate replaces the original rather than competing with it.

Lecture de la figure de tension MHR0312SA

Deux colonnes suivent la valeur indiquée : 5 kV pour usage unique et 7.5 kV pour usage moulé. L’espace entre les colonnes correspond à l’enrobage, et non à la résistance elle-même. Un composant de remplacement proposé au prix indiqué pour un composant moulé, sans l’enrobage, n’est pas identique. Veuillez donc préciser le milieu et la tension de service dans votre demande afin que le devis soit établi en conséquence.

MHR0312SA ordering codes

Le code est MHR0312SA plus un code de résistance à trois chiffres, une lettre de tolérance et une spécification individuelle à deux chiffres : 70 for single use, 20 Pour une utilisation sur moule. Les valeurs de résistance standard sont 10, 15, 20, 25, 30, 40, 50, 68 et 80 ; le code à trois chiffres comporte deux chiffres significatifs et le nombre de zéros qui suivent.

ResistanceCodeOrdering number (±1%, single use)
1 MΩ105MHR0312SA105F70
1.5 MΩ155MHR0312SA155F70
2 MΩ205MHR0312SA205F70
2.5 MΩ255MHR0312SA255F70
3 MΩ305MHR0312SA305F70
4 MΩ405MHR0312SA405F70
5 MΩ505MHR0312SA505F70
6.8 MΩ685MHR0312SA685F70
8 MΩ805MHR0312SA805F70
10 MΩ106MHR0312SA106F70
15 MΩ156MHR0312SA156F70
20 MΩ206MHR0312SA206F70
25 MΩ256MHR0312SA256F70
30 MΩ306MHR0312SA306F70
40 MΩ406MHR0312SA406F70
50 MΩ506MHR0312SA506F70
68 MΩ686MHR0312SA686F70
80 MΩ806MHR0312SA806F70
100 MΩ107MHR0312SA107F70
150 MΩ157MHR0312SA157F70
200 MΩ207MHR0312SA207F70
250 MΩ257MHR0312SA257F70
300 MΩ307MHR0312SA307F70
400 MΩ407MHR0312SA407F70
500 MΩ507MHR0312SA507F70
680 MΩ687MHR0312SA687F70
800 MΩ807MHR0312SA807F70
1000 MΩ (1 GΩ)108MHR0312SA108F70

Lettres de tolérance : D ±0.5 %, F ±1 %, G ±2 %, J ±5 %, K ±10 %, M ±20 %. Remplacer F with the tolerance you need, and 70 au 20 pour les spécifications moulées. HVC fabrique toutes les valeurs de la gamme selon le même gabarit.

MHR0312SA replacement FAQ

Dois-je avoir acheté le MHR0312SA auparavant ?

No. Most enquiries arrive with a part number and no purchase history - a repair, a legacy drawing, or a design inherited from another team. Send the number and the quantity; HVC quotes a substitute against the printed outline rather than asking for an order history.

Le boîtier MHR0312SA est-il toujours disponible ?

HVC supplies the HVRGHP5.13 plate cut to 12.6 mm, 5 mm high, with the lead pitch set to 10.16 mm. This size is cut to drawing, the same CNC process used on the KOA RK92 SIP line.

What does the voltage figure actually mean?

Murata indique deux valeurs : 5 kV pour usage unique et 7.5 kV pour usage moulé. La valeur la plus élevée dépend de la pièce à enrober. HVC indique une tension de service continue dans l’air ; comparez donc les valeurs mesurées dans l’air avec celles mesurées dans l’air et demandez le milieu utilisé pour tout produit de substitution proposé.

Les systèmes HVC peuvent-ils fournir des valeurs en dehors de la plage de 1 à 1000 MΩ ?

Yes. Murata builds nine resistance steps; HVC builds any value in the range, which is the usual reason a buyer with a MHR0312SA drawing cannot simply re-order the original.

Autres tailles de substrat MHR

Famille HVC utilisée sur cette page : GHP flat-style plate resistor.

Devis technique / Réponse sous 6 heures

ENVOYEZ-NOUS LES SPÉCIFICATIONS. NOUS NOUS OCCUPERONS DE LA SOLUTION.

Veuillez nous communiquer la référence de la pièce, le dessin, la fiche technique ou la nomenclature. Le service commercial et d'ingénierie de HVC vous proposera une solution adaptée et un devis.

Demande de devis technique