Murata · Japan · SIP thick film

Résistance de remplacement haute tension série Murata MHR0419SA

MHR0419SA is the substrate series, not a complete part number: the 20.2 mm long, 6.5 mm high member of the Murata MHR SIP line, 1.2 W, 8 kV single use and 14 kV once molded. HVC builds the same outline as a thick film plate with a cut body, so the lead pitch and the seated height stay where the PCB expects them.

Résistance haute tension à couche épaisse SIP remplaçant la Murata MHR0419SA

Référence croisée MHR0419SA

ItemMurata MHR0419SAHVC alternative
Body (L × H)20.2 × 6.5 mm6.5 mm high, cut to 20.2 mm long, cut to 20.2 mm
Lead pitch17.78 mmSame, set on the drawing
Rated power1.2 W2 W
Rated voltage8 kV single / 14 kV molded7.5 kV air, continuous
Resistance1–2000 MΩ, nine stepsAny value in range
ModelMHR0419SAHVRGHP6.20

Same outline. Murata figures are the catalogue values for this body. HVC ratings are continuous values in air. Confirm the medium and the duty in the RFQ.

Pourquoi les acheteurs arrivent avec un numéro MHR0419SA

Il ne s'agit généralement pas d'un bon de commande. C'est une réparation, un plan provenant d'une machine plus ancienne ou une conception héritée d'un fournisseur qui ne la prend plus en charge. Le numéro est la seule information fiable, et la question est simplement de savoir si la pièce est encore disponible selon les spécifications du plan.

That is a different question from price. Murata builds MHR0419SA in nine resistance steps; anything between the steps, anything above 1.2 W, or anything above 8 kV in air has no catalogue answer at all, and that is where a cut-to-outline plate replaces the original rather than competing with it.

Lecture de la figure de tension MHR0419SA

Deux colonnes suivent la valeur indiquée : 8 kV pour usage unique et 14 kV pour usage moulé. L’espace entre les colonnes correspond à l’enrobage, et non à la résistance elle-même. Un composant de remplacement proposé au prix indiqué pour un composant moulé, sans l’enrobage, n’est pas identique. Veuillez donc préciser le milieu et la tension de service dans votre demande afin que le devis soit établi en conséquence.

MHR0419SA ordering codes

Le code est MHR0419SA plus un code de résistance à trois chiffres, une lettre de tolérance et une spécification individuelle à deux chiffres : 70 for single use, 20 Pour une utilisation sur moule. Les valeurs de résistance standard sont 10, 15, 20, 25, 30, 40, 50, 68 et 80 ; le code à trois chiffres comporte deux chiffres significatifs et le nombre de zéros qui suivent.

ResistanceCodeOrdering number (±1%, single use)
1 MΩ105MHR0419SA105F70
1.5 MΩ155MHR0419SA155F70
2 MΩ205MHR0419SA205F70
2.5 MΩ255MHR0419SA255F70
3 MΩ305MHR0419SA305F70
4 MΩ405MHR0419SA405F70
5 MΩ505MHR0419SA505F70
6.8 MΩ685MHR0419SA685F70
8 MΩ805MHR0419SA805F70
10 MΩ106MHR0419SA106F70
15 MΩ156MHR0419SA156F70
20 MΩ206MHR0419SA206F70
25 MΩ256MHR0419SA256F70
30 MΩ306MHR0419SA306F70
40 MΩ406MHR0419SA406F70
50 MΩ506MHR0419SA506F70
68 MΩ686MHR0419SA686F70
80 MΩ806MHR0419SA806F70
100 MΩ107MHR0419SA107F70
150 MΩ157MHR0419SA157F70
200 MΩ207MHR0419SA207F70
250 MΩ257MHR0419SA257F70
300 MΩ307MHR0419SA307F70
400 MΩ407MHR0419SA407F70
500 MΩ507MHR0419SA507F70
680 MΩ687MHR0419SA687F70
800 MΩ807MHR0419SA807F70
1000 MΩ (1 GΩ)108MHR0419SA108F70

Lettres de tolérance : D ±0.5 %, F ±1 %, G ±2 %, J ±5 %, K ±10 %, M ±20 %. Remplacer F with the tolerance you need, and 70 au 20 pour les spécifications moulées. HVC fabrique toutes les valeurs de la gamme selon le même gabarit.

MHR0419SA replacement FAQ

Dois-je avoir acheté le MHR0419SA auparavant ?

No. Most enquiries arrive with a part number and no purchase history - a repair, a legacy drawing, or a design inherited from another team. Send the number and the quantity; HVC quotes a substitute against the printed outline rather than asking for an order history.

Le boîtier MHR0419SA est-il toujours disponible ?

HVC supplies the HVRGHP6.20 plate cut to 20.2 mm, 6.5 mm high, with the lead pitch set to 17.78 mm. This size is cut to drawing, the same CNC process used on the KOA RK92 SIP line.

What does the voltage figure actually mean?

Murata indique deux valeurs : 8 kV pour usage unique et 14 kV pour usage moulé. La valeur la plus élevée dépend de la pièce à enrober. HVC indique une tension de service continue dans l’air ; comparez donc les valeurs mesurées dans l’air avec celles mesurées dans l’air et demandez le milieu utilisé pour tout produit de substitution proposé.

Les systèmes HVC peuvent-ils fournir des valeurs en dehors de la plage de 1 à 2000 MΩ ?

Yes. Murata builds nine resistance steps; HVC builds any value in the range, which is the usual reason a buyer with a MHR0419SA drawing cannot simply re-order the original.

Autres tailles de substrat MHR

Famille HVC utilisée sur cette page : GHP flat-style plate resistor.

Devis technique / Réponse sous 6 heures

ENVOYEZ-NOUS LES SPÉCIFICATIONS. NOUS NOUS OCCUPERONS DE LA SOLUTION.

Veuillez nous communiquer la référence de la pièce, le dessin, la fiche technique ou la nomenclature. Le service commercial et d'ingénierie de HVC vous proposera une solution adaptée et un devis.

Demande de devis technique